Collimating Orion StarMax and Apex Maksutov Cassegrain Telescopes StarMax 90 102 and 127 Apex 90 102 and 127 9821 9824 9826 9820 9823 9825 Collimating is the process of aligning a telescope s optics Your StarMax or Apex s primary mirror was aligned at the factory and should not need adjustment unless the telescope is handled roughly This manual contains information on how to test the collimation of your telescope and instructions for proper alignment should that be needed Star Testing the Telescope Before you start adjusting the primary mirror of your tele scope make certain that it is actually out of collimation by performing a star test Take your telescope out at dusk and let it acclimate to the outside temperature this usually takes 30 60 m ...